Vibration monitoring systems

Rack-based machinery protection for critical machines, and the software that trends and diagnoses what it measures.

Request this catalogue

API 670 machinery protection system

A rack-mounted system that monitors rotating machines continuously and raises alert and danger alarms before a fault becomes a failure. It is built to API 670 for vibration measurement and machinery protection.

Used on: Turbines, generators, compressors, pumps, fans and gearboxes

  • 4 to 32 vibration or multifunction channels (RTD or 4–20 mA), plus up to 4 phase-reference channels
  • Inputs from accelerometers, velocity sensors, proximity probes, tachometers and RTDs
  • Radial vibration, axial displacement, case expansion, speed and reverse-rotation detection
  • Alert and danger relays with a user-set delay of 1 to 60 seconds
  • RS-485 Modbus RTU to the HMI, Ethernet to the monitoring software
  • 19-inch rack mounting
Specifications
Inputs
Vibration channels4 to 32, vibration or multifunction (RTD or 4–20 mA)
Phase referenceUp to 4 channels
Sensor typesIEPE / voltage-mode accelerometer, proximity probe, velocity sensor, tachometer, RTD, 4–20 mA
Input connectorScrew terminal
Signal processing
Frequency response2 to 10,000 Hz (acceleration, velocity, displacement)
Dynamic range90 dB
Accuracy1 % of full scale
Detection modeRMS, true peak, true peak-to-peak
Outputs and relays
Analog outputsFour 4–20 mA per card
Logic outputs8 per card (4 alert, 4 danger), 1 malfunction
RelaysForm C, SPDT, 1 A at 110 V AC, latching or non-latching
Alarm delay1 to 60 seconds, user defined
Communication
To HMI3 redundant RS-485 ports, Modbus RTU
To monitoring softwareEthernet, 10/100 Base-T
Physical and environment
Power supply110 / 220 V AC / DC
HousingAluminium alloy
Mounting19″ rack
Dimensions445 × 277 × 259 mm
Weight5.6 kg
ProtectionIP 55
Operating temp.−20 to +60 °C
Humidity95 % max, non-condensing

ReliMon condition monitoring software

Web-based software that collects live data from the protection system and the wireless sensors, and gives the maintenance team the plots they need to diagnose a machine.

Used on: Plants that trend machine health across many assets

  • Time waveform, FFT, orbit, phase, Bode and waterfall plots
  • Trend analysis and harmonic trend monitoring
  • Alarm thresholds you set, with an alarm history log
  • Automated reports
  • Runs on Windows and Linux, with SCADA and PLC integration

Vibration sensors

Sensors that fit to the machine: a loop-powered transmitter for a direct 4–20 mA signal, and proximity probes for shaft vibration.

Request this catalogue
UI-420

Loop-Powered Vibration Transmitter

A preconfigured 4–20 mA signal proportional to RMS velocity, powered directly from the DCS or PLC loop — in a sealed IP67 stainless-steel body.

Used on: ID, FD and PA fans, blowers, compressors, CW pumps, motors, gearboxes, conveyors and cooling towers

  • Loop-powered 4–20 mA, direct to DCS or PLC
  • Output proportional to RMS velocity (mm/s)
  • Five ranges, 0–10 to 0–100 mm/s RMS
  • Frequency response 10 Hz to 1 kHz
  • IP67 sealed stainless-steel case
  • Base isolated, case isolation >10⁸ Ω
SpecificationsDatasheet UI-420/DS, 2026, version 1.0
Technical performance
Base resonance5 kHz (min), mounted
Range0–10 to 0–100 mm/s RMS (5 ranges)
Freq. response10 Hz to 1 kHz, ±5 %
IsolationBase isolated
Measurement range50 g peak
Transverse sens.Less than 5 %
Mechanical
Case materialStainless steel
Sensing elementPZT, compression
Mounting torque8 Nm
Weight155 g (nominal)
Electrical
Output current4–20 mA DC, ∝ RMS velocity
Supply voltage15–30 V DC
Settling time2 seconds
Loop resistance600 Ω max at 24 V
Case isolation> 10⁸ Ω at 500 V
Environmental
Operating temp.−25 to +90 °C
SealingIP67
Maximum shock5000 g
EmissionsEN 61000-6-4:2001
ImmunityEN 61000-6-2:1999

Proximity probes

Non-contact displacement sensors for shaft vibration on critical rotating machinery. They are used to monitor bearing clearance, rotor dynamics and axial position.

Used on: Turbines, generators and large compressors

  • Non-contact measurement of the shaft itself
  • Suited to high-speed rotating equipment
  • Supplied as a system: probe, extension cable, driver and mounting hardware
  • Works with standard monitoring systems

Wireless IoT sensors

Wireless vibration and temperature monitoring for machines where running cable is not practical.

Request this catalogue

Wixson SyncLeap wireless vibration sensor

By Wixson, Germany

A wireless sensor that measures vibration on three axes together with temperature. Several sensors can acquire at the same moment, synchronised to a tacho signal, which supports analysis on machines that change speed.

Used on: Wind turbines, motors, pumps, fans and gearboxes

  • Three-axis acceleration and velocity, plus temperature
  • Selectable range of ±2, ±4, ±8 or ±16 g
  • Sampling rate from 500 to 12,000 Hz
  • Wi-Fi, with Modbus TCP, HTTP and FTP data transfer
  • 24 V DC supply, with an optional battery
  • Stud, magnet or adhesive pad mounting
Specifications
Measurement
Axes3: acceleration, velocity, gravity
TemperatureMeasured with vibration
Range±2 g / ±4 g / ±8 g / ±16 g
Sampling rate500 to 12,000 Hz
Samples per channel500 to 72,000
Low-pass filter50 to 1,000 Hz
High-pass filter0.1 to 1 Hz
Power, connectivity and mounting
Power supply24 V DC, optional battery
ConnectivityWi-Fi access point / client, Modbus TCP, HTTP, FTP
SynchronisationSimultaneous sensor acquisition with synchronised tacho; external pulse input
MountingStud, magnet or adhesive mounting pad

Portable instruments

Hand-held instruments for walk-round checks and on-site diagnosis.

Request this catalogue

Portable vibration pen

A pocket-size vibration meter for quick overall readings on routine rounds. Hold it to the bearing housing, read the level, and decide whether the machine needs a closer look.

Used on: Motors, pumps, fans and gearboxes

  • Quick overall vibration checks
  • Pocket size for daily rounds
  • Specifications on request

Vibration analyzers

Portable analyzers for finding the cause of vibration on site, using spectrum (FFT) and time-waveform analysis.

Used on: Maintenance and reliability teams

  • Spectrum (FFT) and time-waveform analysis
  • Used to find unbalance, misalignment, looseness and bearing faults
  • Specifications on request

Speed monitoring

RPM indication with alarm relays, from a proximity sensor or a magnetic pickup.

Request this catalogue
UI-500

Speed (RPM) Indicator Controller

Proximity or magnetic-pickup pulse input, 4-digit LED display, up to two relays, RS485 Modbus and isolated retransmission — in a 96 × 48 mm panel instrument.

Used on: Generators, turbines, and online speed monitoring in automotive, sugar and pharma plants

  • PNP, NPN and magnetic pickup sensor inputs
  • Large 0.54″ 4-digit red LED display
  • Programmable range and decimal point
  • Up to 2 relays: LO-LO, LO, HI, HI-HI alarms
  • Optional RS485 Modbus RTU/ASCII interface
  • Optional isolated 4–20 mA / 0–10 V output
SpecificationsDatasheet UI-500/DS, 2026, version 1.0
Inputs
No. of inputsOne
Sensor typesPNP / NPN proximity sensor, magnetic pickup
Range0–9999 RPM (PNP / NPN)
Decimal pointProgrammable
Accuracy0.25 % of FS ±1 count
Display
Display type0.54″ 7-segment red LED
No. of digits4
Relay status3 mm red LED
Comm. status3 mm red LED
Alarms (optional)
No. of relays1 / 2
Contact typeNO-C-NC
Contact rating5 A / 230 V AC, resistive
Alarm selectionLO-LO, LO, HI, HI-HI
Relay modeEach relay LO or HI settable
HysteresisAdjustable throughout range
Environment & power
Operating temp.0 to +70 °C
Storage temp.−20 to +85 °C
Humidity0–95 % RH
Supply110 / 230 V AC ±10 %, 50/60 Hz
Communication (optional)
PortRS485
ProtocolModbus RTU / ASCII
Baud rate1200–19200 bps, programmable
Slave ID1–255, programmable
Min. polling250 ms
Process valuesRead only
SetpointsRead & write from host
Alarm statusRead & write
Relay statusRead only
Retransmission (optional)
Current output4–20 mA, isolated
Load< 600 Ω
or Voltage output0–10 V DC, isolated
Load> 10 kΩ
Enclosure
MaterialABS plastic
Bezel96 × 48 mm
Depth65 mm (1 relay), 110 mm (2 relays)
Panel cutout92 (+0.5) × 45 (+0.5) mm
Cutout spacing≥ 110 mm horizontal, ≥ 55 mm vertical, centre to centre
MountingFlush panel mount
UI-600

DIN-Rail RPM Indicator Controller

Proximity or magnetic-pickup pulse input, 4-digit LED display, up to two relays, RS485 Modbus and isolated retransmission — in a 55 mm wide DIN-rail housing.

Used on: In-panel speed indication with retransmission to a remote display

  • Microcontroller-based DIN-rail controller
  • PNP, NPN and magnetic pickup sensor inputs
  • 0.4″ 4-digit red LED display
  • Up to 2 relays: LO-LO, LO, HI, HI-HI alarms
  • Optional RS485 Modbus RTU/ASCII interface
  • Optional isolated 4–20 mA / 0–10 V output
SpecificationsDatasheet UI-600/DS, 2026, version 1.0
Inputs
No. of inputsOne
Sensor typesPNP / NPN proximity sensor, magnetic pickup
RangeProgrammable
Decimal pointProgrammable
Accuracy0.25 % of FS ±1 count
Display
Display type0.4″ 7-segment red LED
No. of digits4
Relay status3 mm red LED
Comm. status3 mm red LED
Alarms (optional)
No. of relays1 / 2
Contact typeNO-C-NC
Contact rating5 A / 230 V AC, resistive
Alarm selectionLO-LO, LO, HI, HI-HI
Relay modeEach relay LO or HI settable
HysteresisAdjustable throughout range
Environment & power
Operating temp.0 to +70 °C
Storage temp.−20 to +85 °C
Humidity0–95 % RH
Supply110 / 230 V AC ±10 %, 50/60 Hz
Communication (optional)
PortRS485
ProtocolModbus RTU / ASCII
Baud rate1200–19200 bps, programmable
Slave ID1–255, programmable
Min. polling250 ms
Process valuesRead only
SetpointsRead & write from host
Alarm statusRead & write
Relay statusRead only
Retransmission (optional)
Current output4–20 mA, isolated
Load< 600 Ω
or Voltage output0–10 V DC, isolated
Load> 10 kΩ
Enclosure
MaterialABS plastic
Dimensions55 (W) × 70 (H) × 110 (D) mm
MountingDIN rail

Process instruments

Panel and DIN-rail instruments that indicate, isolate and record process signals.

Request this catalogue
UI-200

Process Indicator Controller

One universal input, a large 4-digit LED display, up to two relays, RS485 Modbus and isolated retransmission — in a compact 96 × 48 mm panel instrument.

Used on: Process plants, pharma rooms, testing and calibration labs, cold storage and dairies

  • Universal input: RTD, thermocouple, mA, V, mV
  • Large 0.8″ 4-digit red LED display
  • Programmable set point and hysteresis
  • Up to 2 relays: LO-LO, LO, HI, HI-HI alarms
  • Optional RS485 Modbus RTU/ASCII interface
  • Optional isolated 4–20 mA / 0–10 V output
SpecificationsDatasheet UI-200/DS, 2026, version 1.0
Inputs
No. of inputsOne
RTDPt100
ThermocoupleJ / K / R / S / T / B
Current0/4–20 mA
Voltage0/2–10 V DC, 0/1–5 V DC, 0–200 mV DC
RangeProgrammable
Decimal pointProgrammable
Accuracy0.25 % of FS ±1 count
Display
Display type0.8″ 7-segment red LED
No. of digits4
Relay status3 mm red LED
Comm. status3 mm red LED
Retransmission (optional)
Current output4–20 mA, isolated
Load< 600 Ω
or Voltage output0–10 V DC, isolated
Load> 10 kΩ
Environment & power
Operating temp.0 to +70 °C
Storage temp.−20 to +85 °C
Humidity0–95 % RH
Supply110 / 230 V AC ±10 %, 50/60 Hz
Alarms (optional)
No. of relays1 / 2
Contact typeNO-C-NC
Contact rating5 A / 230 V AC, resistive
Alarm selectionLO-LO, LO, HI, HI-HI
Relay modeEach relay LO or HI settable
HysteresisAdjustable throughout range
Communication (optional)
PortRS485
ProtocolModbus RTU / ASCII
Baud rate1200–19200 bps, programmable
Slave ID1–255, programmable
Min. polling250 ms
Process valuesRead only
SetpointsRead & write from host
Alarm statusRead & write
Relay statusRead only
Enclosure
MaterialABS plastic
Bezel96 × 48 mm
Depth65 mm (1 relay), 110 mm (2 relays)
Panel cutout92 × 44 mm
MountingFlush panel mount
UI-300

Signal Isolator / Converter

Galvanically isolated single or dual output for current and voltage signals, with three-port isolation — in a compact 22 mm DIN-rail module.

Used on: Isolated field signals for PLC and DCS inputs, data loggers and control valves

  • Compact 22 mm wide DIN-rail module
  • Current, voltage and shunt (mV) inputs
  • Three-port isolation: input, output, supply
  • Converts voltage to current and vice versa
  • Single or dual output options
  • DC or AC supply to suit the requirement
SpecificationsDatasheet UI-300/DS, 2026, version 1.0
Input
No. of inputsOne
Input typePredefined
Voltage0–10 V DC / 0–5 V DC
Current4–20 mA / 0–20 mA
Shunt input0–100 mV
Output
No. of outputsOne / Two
Current0–20 mA DC, 4–20 mA DC
Voltage0–5 V, 0–10 V DC
Input / output load
Current input62 Ω input impedance
Voltage input10 kΩ/V input impedance
Current output< 600 Ω load
Voltage output> 1 kΩ/V load
Accuracy
Accuracy0.25 % of full span
Isolation
Isolated portsInput, output and power supply
Test voltage1000 V AC RMS for 1 minute
Continuous250 V AC RMS
Power supply
Supply voltage16–36 V DC, or 85–265 V AC, 50 Hz
Power indication3 mm red LED
Enclosure & connections
MaterialABS plastic
Dimensions22 (W) × 75 (H) × 110 (D) mm
MountingSnap-on, 35 mm DIN rail
CalibrationFront side
Wire size< 2.5 mm², 14 AWG, single / multistrand
Environment
Operating temp.0 to +60 °C
Storage temp.−20 to +85 °C
Humidity0–95 % RH
UI-100

8 / 16-Channel Touchscreen Data Logger

Universal inputs, 3.5″ colour TFT, USB pen-drive logging in CSV and Modbus RS485 — in a compact 96 × 96 mm panel instrument.

Used on: Bearing, winding and transformer temperatures, furnace and cooling-water monitoring, 4–20 mA field signals

  • 8/16 universal inputs: TC J/K, Pt100, 0–10 V, 4–20 mA
  • 3.5″ TFT touchscreen, many channels at a glance
  • USB pen-drive logging in CSV, opens in Excel
  • Built-in real-time clock for time-stamped data
  • LO-LO/LO/HI/HI-HI alarms, up to 4 relays
  • RS485 Modbus RTU/ASCII to SCADA and gateways
SpecificationsDatasheet UI-100/DS, 2026, version 1.0
Inputs
No. of inputs8 / 16
Input typesThermocouple J / K, RTD Pt100, 0–10 V DC, 4–20 mA
RangeProgrammable
Decimal pointProgrammable
Accuracy0.25 % of FS ±1 count
Display & data logging
Display3.5″ TFT with touchscreen
StorageUSB pen drive via front host port
File formatCSV — new file each time a drive is connected
Log interval1–99 minutes, settable
ClockBuilt-in RTC
Alarms (optional)
No. of relays2 / 4
Contact typeNO-C-NC
Contact rating5 A / 230 V AC, resistive
Alarm selectionLO-LO, LO, HI, HI-HI
Relay modeEach relay LO or HI settable
HysteresisAdjustable throughout range
Environment & power
Operating temp.0 to +70 °C
Storage temp.−20 to +85 °C
Humidity0–95 % RH
Supply110 / 230 V AC ±10 %, 50/60 Hz
Communication (optional)
PortRS485 (RS232 on request)
ProtocolModbus RTU / ASCII
Baud rate1200–19200 bps, programmable
Slave ID1–255, programmable
Min. polling250 ms
Process valuesRead only
SetpointsRead & write from host
Alarm statusRead & write
Relay statusRead only
Retransmission (optional)
Current output4–20 mA for selected channel
Load< 330 Ω
or Voltage output0–10 V DC
Load> 10 kΩ
Enclosure
MaterialMS fabricated, powder coated
Bezel96 × 96 mm
Depth150 mm
Panel cutout92 × 92 mm
MountingFlush panel mount